Wolf Bavaria GmbH Wolf Bavaria GmbH

PhoneStar

Registration Code: EC91XK

Quality phase Sentinel Holding Institut GmbH
ENV1.2 Version 2018 Risiken für die lokale Umwelt
not relevant for consideration
ENV1.2 Version 2023 Risiken für die lokale Umwelt
not relevant for consideration
ENV1.2 Version 2023 Risiken für die lokale Umwelt
not relevant for consideration
Holz und Holzwerkstoffe (u. nachw. Rohstoffe)
Mineralische Baustoffe

Product description

PhoneStar TRI

Schalldämmplatte + Trockenestrich

PhoneStar TRI Schalldämmplatte und Trockenestrich ist eine mit hochverdichtetem Quarzsand gefüllte Wellkartonplatte mit einer dreiwellig parallelen Innenstruktur.

PhoneStar ST TRI

Schalldämmplatte + Trockenestrich

PhoneStar ST TRI Schalldämmplatte und Trockenestrich ist eine mit hochverdichtetem Quarzsand gefüllte besonders dünne Wellkartonplatte mit einer dreiwellig parallelen Innenstruktur.

PhoneStar Twin

Schalldämmplatte + Trockenestrich

PhoneStar TWIN Schalldämmplatte und Trockenestrich ist eine mit hochverdichtetem Quarzsand gefüllte Wellkartonplatte mit einer zweiwellig parallelen Innenstruktur.

PhoneStar 25

Schalldämmplatte + Boden-Beschwerungsplatte

Boden-Beschwerungsplatte als Schüttungsersatz.

PhoneStar Schalli

Nicht lastabtragender Entkopplungsstreifen

Nicht lastabtragende Schallentkopplung für Wand und Decke.

Wolf Tape

Klebeband

Versiegelungsband für PhoneStar Platten

Wolf Tape ST

Klebeband

Versiegelungsband für PhoneStar ST Platten

Instructions for use

* Panels must be stored flat, dry, frost-free and indoors only. Edges must be protected from damage during transport and handling.
* Allow panels to acclimatise at the installation location for at least 24 hours prior to installation.
* The substrate must be clean, dry, level and load-bearing.
* Panels can be cut using standard tools for wood-based materials. All cut edges must be sealed with Wolf adhesive tape to protect the sand filling and maintain acoustic performance.
* Install panels tightly butted and in a staggered pattern, with the visible side facing upwards.
* Do not expose panels to direct moisture or high humidity.
* Offcuts can be disposed of as non-hazardous construction waste.
* Observe safety measures: avoid dust generation during cutting and wear protective gloves, a dust mask and safety goggles.

Reference to the DGNB system

ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
1.00E-2
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
6.55E-4
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
2.15E-3
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Unit
kg NMVOC-Equivalent
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Total use of non-renewable primary energy (PENRT)
1) Production stage
37.7 MJ
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
1.03 MJ
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
11.9 MJ
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Total use of renewable primary energy (PERT)
1) Production stage
23.4 MJ
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
4.63E-2 MJ
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
-3.57 MJ
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
General life cycle assessment data
Building material class
E
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Reference Unit
m²
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
End of life cycle
Modules C1–C4 + D (cradle-to-gate incl. end-of-life)
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Useful life
40 years
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Global Warming Potential (GWP)
1) Production stage
-4.70E-1
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
2.32
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
-7.42E-1
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Unit
kg CO2-Equivalent
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Eutrophication (EP)
1) Production stage
1.10E-4 ; 4.05E-3 ; 3.68E-2
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
0 ; 0 ; 0
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
1.75E-6 ; 1.96E-4 ; 2.12E-3
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
4.47E-5 ; 1.34E-3 ; 9.45E-3
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Unit
kg P-Eq. [EP-freshwater]; kg N-Eq. [EP-marine]; mol N-Eq. [EP-terrestrial]
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Acidification potential (AP)
1) Production stage
1.34E-2
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
5.46E-4
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
3.60E-3
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Unit
mol H+- Equivalent
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Ozone Depletion Potential (ODP)
1) Production stage
1.39E+0
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
2) Use stage
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
3) End of life stage
1.61E-8
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
4) Benefits and loads beyond the system boundries
5.74E-8
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
Unit
kg CFC11-Equivalent
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
ECO1.1 Life cycle costs
ECO1.1 Life cycle costs
Actual useful life
4o Years
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]
PRO1.4 Ensuring sustainability aspects in tendering and contracting
PRO1.4 Ensuring sustainability aspects in tendering and contracting
Tender textes
Specification texts and EPD data available (EPD-Kiwa-EE-215909-EN, QNG/Sentinel certified)
Source
EPD-Kiwa-EE-215909-EN / Technical Data sheet
Quality
[Unaudited manufacturer specification]
PRO2.5 Preparation of sustainable use
PRO2.5 Preparation of sustainable use
Maintenance, inspection, operating and care instructions
Product requires no maintenance. Installation and handling instructions available.
Source
User Guide-Wolf Bavaria / Technical data sheet
Quality
[Unaudited manufacturer specification]
SOC1.3 Acoustic comfort
SOC1.3 Acoustic comfort
Rated building sound insulation value R`w
38 dB
Source
EPD-Kiwa-EE-215909-EN
Quality
[Externally audited industry specification]

Documents

Downloads

Leistungserklärung

pdf
Sentinel Holding Institut GmbH

Broschüre

pdf
Sentinel Holding Institut GmbH

Leistungserklärung

pdf
Sentinel Holding Institut GmbH

Technisches Merkblatt

pdf
Sentinel Holding Institut GmbH

Technisches Merkblatt

pdf
Sentinel Holding Institut GmbH

Broschüre

pdf
Sentinel Holding Institut GmbH

SHI-Produktpass PhoneStar

pdf
Sentinel Holding Institut GmbH

Technisches Merkblatt

pdf
Sentinel Holding Institut GmbH

Technisches Merkblatt

pdf
Sentinel Holding Institut GmbH

Technisches Merkblatt

pdf
Sentinel Holding Institut GmbH

Leistungserklärung

pdf
Sentinel Holding Institut GmbH

Leistungserklärung

pdf
Sentinel Holding Institut GmbH

Technisches Merkblatt

pdf
Sentinel Holding Institut GmbH

Leistungserklärung

pdf
Sentinel Holding Institut GmbH

Leistungserklärung

pdf
Sentinel Holding Institut GmbH

SHI-Produktpass PhoneStar

pdf
Sentinel Holding Institut GmbH

Contact the manufacturer

Wolf Bavaria GmbH

Wolf Bavaria GmbH

Wolf Bavaria GmbH

Gutenbergstraße 8
91560 Heilsbronn

Related products from this manufacturer

#8BERRE

PowerFloor Slim

Wolf Bavaria GmbH
Flächenheizung in Trockenbauweise mit und ohne Alu-Dickfolie
Read more
#3XY0HW

PowerFloor Slim

Wolf Bavaria GmbH
Flächenheizung in Trockenbauweise mit und ohne Alu-Dickfolie
Read more
#Z2RPPN

PhoneStrip

Wolf Bavaria GmbH
PhoneStrip Lastabtragender Entkopplungsstreifen PhoneStrip ist ein lastabtragender und setzungssicherer Dämmstreifen der universell als schalldämmende Entkopplungslage eingesetzt wird. PhoneStrip Tape Klebeband Versiegelungsband für PhoneStrip…
Read more
Contact

DGNB GmbH
Tübinger Straße 43
70178 Stuttgart
Germany

Phone: +49 711 72 23 22 - 0
Fax: +49 711 72 23 22 - 99
navigator@dgnb.de

Legal
  • Contact
  • Imprint
  • Data protection
  • General terms and conditions
www.dgnb-akademie.de www.dgnb.de www.dgnb-system.de
Nutzung eines veralteten Browsers

Um Ihre Internet-Erfahrung sicherer und so angenehm wie möglich zu gestalten, sollten Sie Ihren Browser hier auf eine neue Version updaten. Das Update ist kostenlos. Wenn Sie diesen PC auf der Arbeit verwenden, sollten Sie Ihren IT-Administrator kontaktieren. Bitte beachten Sie, dass aufgrund des veralteten Browsers diese Webseite unter Umständen nicht korrekt dargestellt wird.