DGNB Navigator
  • DE
  • DGNB Navigator
  • Product database
  • About the DGNB Navigator
    • About the DGNB Navigator
    • For manufacturers
    • For architects and planners
    • For DGNB Auditors
    • DGNB Navigator label
    • Downloads
    • Contact and inquiries
    • FAQ
  • Building products in the DGNB System
    • Building products in the DGNB System
    • Quality Level Assessment
    • ENV1.1 Building life cycle assessment
    • ENV1.2 Local environment impact
  • Fees
  • Login
  • DE
www.dgnb-akademie.de www.dgnb.de www.dgnb-system.de
  1. Home
  2. Product database
  3. Product
Tecnostrutture Deutschland GmbH Tecnostrutture Deutschland GmbH

NPS PDTI Composite Column

Registration Code: B3VOC6

Metalle

Product description

The PDTI® NPS® Column is EN1090-1 CE marked. It offers high load-bearing capacities while maintaining compact cross-sections.

It is suitable for maximum space utilisation and also for construction in seismic areas. It offers integrated fire resistance without the need for additional work on site.

The PDTI® NPS® Column is suitable for multi-storey buildings such as hospitals, hotels, shopping centres, residential buildings as well as infrastructure. It can be supplied with circular, square ore rectangular section.

After the placement, it is filled with concrete on site. It can be supplied in a multi-storey version, also with a different cross-section for each inter-storey. By installing a three-storey PDTI® NPS® column, the vertical element for the upper two storeys is already in place - a considerable time saver.

Instructions for use

BENEFITS
Native fire resistance
Compact sections
High load capacities
Seismic-resistant solution without bracing
Quick and easy to assemble
Available in multi-storey version to speed up assembly
Construction site safety

AREAS OF USE
Industrial building
Civil construction
Tertiary
Accommodation facilities
Hospital facilities
High buildings
Infrastructure
Renovations
Elevations

Reference to the DGNB system

ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
1,12E-02
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-5,40E-03
Source
EPD
Quality
[Externally audited specific manufacturer information]
Unit
kg NMVOC-Equivalent
Source
EPD
Quality
[Externally audited specific manufacturer information]
Total use of non-renewable primary energy (PENRT)
1) Production stage
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
Total use of renewable primary energy (PERT)
1) Production stage
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
nicht relevant MJ
Source
EPD
Quality
[Externally audited specific manufacturer information]
General life cycle assessment data
Building material class
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
Reference Unit
kg
Source
EPD
Quality
[Externally audited specific manufacturer information]
If necessary, conversion of the reference unit
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
End of life cycle
Wieder- und Weiterverwendung: 100% möglich
Source
EPD
Quality
[Externally audited specific manufacturer information]
Useful life
50 Jahre
Source
Basierend auf Gebäudenutzungsdauer
Quality
[Unaudited average or standard value]
Global Warming Potential (GWP)
1) Production stage
2,30E+00
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,05E+00
Source
EPD
Quality
[Externally audited specific manufacturer information]
Unit
kg CO2-Equivalent
Source
EPD
Quality
[Externally audited specific manufacturer information]
Eutrophication (EP)
1) Production stage
1,12E-04
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-6,33E-05
Source
EPD
Quality
[Externally audited specific manufacturer information]
Unit
kg PO4-Equivalent
Source
EPD
Quality
[Externally audited specific manufacturer information]
Acidification potential (AP)
1) Production stage
1,05E-02
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-5,36E-03
Source
EPD
Quality
[Externally audited specific manufacturer information]
Unit
mol H+- Equivalent
Source
EPD
Quality
[Externally audited specific manufacturer information]
Ozone Depletion Potential (ODP)
1) Production stage
1,40E-07
Source
EPD
Quality
[Externally audited specific manufacturer information]
2) Use stage
nicht relevant
Source
EPD
Quality
[Externally audited specific manufacturer information]
3) End of life stage
Source
EPD
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3,92E-08
Source
EPD
Quality
[Externally audited specific manufacturer information]
Unit
kg CFC11-Equivalent
Source
EPD
Quality
[Externally audited specific manufacturer information]

Documents

Downloads

Tecnostrutture_dgbn_de_51394.pdf

pdf
1,005 KB

EPD_NPS_PDTI_2021.pdf

pdf
417 KB

Links

Tecnostrutture's Website

Contact the manufacturer

Tecnostrutture Deutschland GmbH

Tecnostrutture Deutschland GmbH

Tecnostrutture Deutschland GmbH

Alfredstr. 81
45130 Essen

Related products from this manufacturer

#PPW9JO

NPS BASIC Träger

Tecnostrutture Deutschland GmbH
Beim selbsttragenden NPS® BASIC Träger in Stahlbetonverbund handelt es sich um einen sogenannten Verbundträger, der für massive Konstruktionen mit großen Spannweiten sowie für Wohn- , Industrie- und Infrastrukturvorhaben verbaut wird. Dieser…
Read more
#9I9RFZ

NPS PTC Stütze - auch als Schleuderbetonstütze

Tecnostrutture Deutschland GmbH
Die Schleuderbetonstütze: ein schlichtes, architektonisches Tragelement, welches nach Zugabe von Farbe, Verchromung oder anderer Oberflächenbehandlungen individuelle Ansprüche erfüllt. Dank der schlanken Bauart dieser Schleuderbetonstütze kann eine…
Read more
Contact

DGNB GmbH
Tübinger Straße 43
70178 Stuttgart
Germany

Phone: +49 711 72 23 22 - 0
Fax: +49 711 72 23 22 - 99
navigator@dgnb.de

Legal
  • Contact
  • Imprint
  • Data protection
  • General terms and conditions
www.dgnb-akademie.de www.dgnb.de www.dgnb-system.de
Nutzung eines veralteten Browsers

Um Ihre Internet-Erfahrung sicherer und so angenehm wie möglich zu gestalten, sollten Sie Ihren Browser hier auf eine neue Version updaten. Das Update ist kostenlos. Wenn Sie diesen PC auf der Arbeit verwenden, sollten Sie Ihren IT-Administrator kontaktieren. Bitte beachten Sie, dass aufgrund des veralteten Browsers diese Webseite unter Umständen nicht korrekt dargestellt wird.