3A Composites GmbH

ALUCOBOND® PLUS, ALUCOBOND® A2

Registration Code: TMCA9E

Metalle

Product description

ALUCOBOND® is a composite panel consisting of two aluminium cover sheets and a fire-retardant or non-combustible mineral-filled core that stands for sustainable construction quality and the highest creative standards. The façade material is distinguished by its outstanding product attributes such as precise flatness, variety of surfaces and colours as well as excellent formability.

The composite structure of ALUCOBOND® consists of corrosion-resistant aluminium cover sheets. Aluminium is an excellent lightweight construction material that requires high primary energy in its initial production, but is suitable for very long service lives in the industrial, transport and construction sectors due to its optimum recycling properties (100% infinitely recyclable).

The ALUCOBOND® core material consists mainly of mineral components that consume little primary energy and are nevertheless 100% recyclable and can be returned to the material cycle.

ALUCOBOND® is used in rear-ventilated façade systems with a high insulating effect, which reduce the heat input in summer and increase a building's protection against the cold in winter.

Cladding on both sides with 0.5 mm thick aluminium sheets Alloy EN AW - 5005A (ALMg1) in accordance with DIN EN 573-3 Condition H22 I H42 in accordance with DIN EN 515
Tensile strength of the cover sheets: Rm ≥ 130 N/mm² according to DIN EN 485-2; yield strength 0.2% Rp0.2 ≥ 90 N/mm² according to DIN EN 485-2
Elongation at break A50 ≥ 5% according to DIN EN 485-2
Core material mineral (building material class B, s1, d0 and A2, s1, d0) according to general building authority approval Z-10.3-774
Surfaces: visible side stove-enamelled using the coil coating process in accordance with ECCA (European Coil Coating Association) guidelines
Gloss level: matt I silk gloss I high gloss (depending on surface)
Visible side laminated with protective film; reverse side mill-finished
Coating qualit: high-quality polymer coating systems

Instructions for use

Panel can be used as a cassette system
Panel can be used as a flat system

Reference to the DGNB system

ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
6.11E-3
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
1.90E-5
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3.54E-3
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Unit
kg C2H4-Equivalent
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Total use of non-renewable primary energy (PENRT)
1) Production stage
4,62E+2 MJ
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
5,53E-1 MJ
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-2,12 E+2 MJ
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Total use of renewable primary energy (PERT)
1) Production stage
1,02E+2 MJ
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
6,86E-2 MJ
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-7,84E+1 MJ
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
General life cycle assessment data
Building material class
ALUCOBOND A2 (DIN EN 13501 A2 s1 d0)ALUCOBOND Plus (DIN EN 13501 B s1 d0)
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Reference Unit
1 sqm
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
End of life cycle
recycling rate 85 %
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Useful life
50 years
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Global Warming Potential (GWP)
1) Production stage
2,67E+1
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
4,13E-2
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,63E+1
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Unit
kg CO2-Equivalent
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Eutrophication (EP)
1) Production stage
7.43E-3
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
3.37E-5
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-4.58E-3
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Unit
kg PO4-Equivalent
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Acidification potential (AP)
1) Production stage
1.00E-1
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
2.44E-4
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-6.36E-2
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Unit
kg SO2-Equivalent
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Ozone Depletion Potential (ODP)
1) Production stage
2.44E-10
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
3) End of life stage
9.15E-15
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1.64E-10
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]
Unit
kg R11-Equivalent
Source
EPD-GDA-2019132-IBG1-DE
Quality
[Externally audited specific manufacturer information]

Documents

Downloads

Datenblatt ALUCOBOND PLUS Halogenfrei

pdf
90 KB

FVHF Nachhaltigkeit

pdf
7 MB

VOC Analysebericht A2

pdf
912 KB

Brandklassifizierung EN 13501-1 ALUCOBOND PLUS.pdf

pdf
8 MB

Datenblatt ALUCOBOND A2 Halogenfrei

pdf
90 KB

Recycling_ALUCOBOND.pdf

pdf
1 MB

Brandklassifizierung EN 13501-1 ALUCOBOND A2.pdf

pdf
5 MB

VOC Analysebericht Plus

pdf
912 KB

Sicherheitsdatenblatt ALUCOBOND Plus

pdf
430 KB

EPD ALUCOBOND

pdf
2 MB

Reinigung ALUCOBOND FASSADEN

pdf
126 KB

Sicherheitsdatenblatt ALUCOBOND A2

pdf
433 KB

Contact the manufacturer

3A Composites GmbH

3A Composites GmbH

Alusingen-Platz 1
78224 Singen

Contact

DGNB GmbH
Tübinger Straße 43
70178 Stuttgart
Germany

Phone: +49 711 72 23 22 - 0
Fax: +49 711 72 23 22 - 99
navigator@dgnb.de

Legal
  • Contact
  • Imprint
  • Data protection
  • General terms and conditions
www.dgnb-akademie.de www.dgnb.de www.dgnb-system.de
Nutzung eines veralteten Browsers

Um Ihre Internet-Erfahrung sicherer und so angenehm wie möglich zu gestalten, sollten Sie Ihren Browser hier auf eine neue Version updaten. Das Update ist kostenlos. Wenn Sie diesen PC auf der Arbeit verwenden, sollten Sie Ihren IT-Administrator kontaktieren. Bitte beachten Sie, dass aufgrund des veralteten Browsers diese Webseite unter Umständen nicht korrekt dargestellt wird.