aquatherm GmbH

aquatherm black

Registration Code: O9Q39P

Product description

aquatherm black is a multiple awarded surface heating and cooling system. Versatile, manufactured in compact register design and equipped with a future-proof technology – these are some of the essential features of aquatherm black. The special feature: It can be installed in the ceiling as well as in the wall and floor. Depending on the requirements, the surface temperature of the elements is driven a few degrees above or below the desired room temperature. The radiant energy provides either pleasant heat or cooling without disturbing draughts or dust turbulence.

aquatherm black works energy-saving thanks to perfect control technology. The system is ideal for use with low temperature systems such as heat pumps. Building owners and architects can be pleased about the flexible areas of application and the associated freedom of design: whether as a cooling ceiling in the office, as wall heating in the bathroom or as underfloor heating in a renovated old building – the possibilities are almost unlimited. Finally, the panel heating and cooling elements can be installed in drywall construction, in plastered ceilings, walls or in suspended coffered ceilings and are invisible afterwards.

Reference to the DGNB system

ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
9.95E-03
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
3.42E-04
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3.49E-03
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
Total use of non-renewable primary energy (PENRT)
1) Production stage
1.75E+02 MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
6.87E-01 MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-5.70E01 MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
Total use of renewable primary energy (PERT)
1) Production stage
7.30E+00 MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
1.34E-01 MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-5.37E-01 MJ
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
General life cycle assessment data
Reference Unit
1 meter of piping system
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
If necessary, conversion of the reference unit
1,765 kg/m2
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
End of life cycle
brass fittings: 100% recycling; remaining pipe system: 100% thermal recycling
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
Useful life
50 years
Source
aquatherm GmbH
Quality
[Unaudited manufacturer specification]
Global Warming Potential (GWP)
1) Production stage
6.26E+00
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
5.27E00
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3.64E00
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
Eutrophication (EP)
1) Production stage
4.95E-05
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
5.72E-08
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3.08E-07
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
Acidification potential (AP)
1) Production stage
8.28E-03
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
5.34E-04
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3.43E-03
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
Ozone Depletion Potential (ODP)
1) Production stage
3.12E-14
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
2) Use stage
Modul nicht deklariert
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
3) End of life stage
4.15E-16
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-4.34E-15
Source
BREG EN EPD No.000477
Quality
[Externally audited specific manufacturer information]

Documents

Downloads

BREGENEPD000477_aquatherm_black_piping_system.pdf

pdf
1 MB

Contact the manufacturer

aquatherm GmbH

aquatherm GmbH

Biggen 5
57439 Attendorn

Related products from this manufacturer

#86CR4E

aquatherm green UV

aquatherm GmbH
aquatherm green hat den Kunststoff-Rohrleitungssektor nicht nur revolutioniert, sondern prägt ihn seit Jahrzehnten. Aufgrund seiner hervorragenden ökologischen Eigenschaften spielt das innovative Allroundtalent aus korrosionsresistentem Polypropylen…
Read more
#K07TF1

aquatherm green ti

aquatherm GmbH
Eine der energieeffizientesten Methoden, warmes Trinkwasser über längere Entfernungen zu transportieren, ist der Einsatz von erdverlegten Rohrleitungen. Um die für diese Anwendungen notwendigen Eigenschaften zu erreichen, bietet aquatherm das…
Read more
#E78BG2

aquatherm blue ti

aquatherm GmbH
Eine der energieeffizientesten Methoden, Heizungs- und Kühlwasser über längere Entfernungen zu transportieren, ist der Einsatz von erdverlegten Rohrleitungen. Um die für diese Anwendungen notwendigen Eigenschaften zu erreichen, bietet aquatherm das…
Read more
Contact

DGNB GmbH
Tübinger Straße 43
70178 Stuttgart
Germany

Phone: +49 711 72 23 22 - 0
Fax: +49 711 72 23 22 - 99
navigator@dgnb.de

Legal
  • Contact
  • Imprint
  • Data protection
  • General terms and conditions
www.dgnb-akademie.de www.dgnb.de www.dgnb-system.de
Nutzung eines veralteten Browsers

Um Ihre Internet-Erfahrung sicherer und so angenehm wie möglich zu gestalten, sollten Sie Ihren Browser hier auf eine neue Version updaten. Das Update ist kostenlos. Wenn Sie diesen PC auf der Arbeit verwenden, sollten Sie Ihren IT-Administrator kontaktieren. Bitte beachten Sie, dass aufgrund des veralteten Browsers diese Webseite unter Umständen nicht korrekt dargestellt wird.